YINTO resistive load banks are designed for testing AC power systems at unity power factor (PF=1). Ranging from 1kW to 1000kW with voltages from 110V to 690V, our resistive series provides precise, reliable load testing for generators, UPS systems, batteries, and power distribution equipment.
Built with corrosion-resistant alloy resistance elements and integrated high-efficiency cooling systems, every unit delivers consistent performance under continuous full-load operation — backed by comprehensive safety protections including over-temperature, over-current, over-voltage, and fan failure safeguards.
The most commonly used resistive load banks, rated 1kW to 1000kW, covering the most common industrial testing requirements. Custom configurations available upon request.
YS-AC100 Load Banks are the smallest, ultra-compact alternating current (AC)load banks in the industry Meanwhile it is rated to do continuous operation with no test interruption
This 200kW portable load bank is designed for testing generators, UPS, backup power systems and energy storage equipment Wi...
300kW and 500kW Resistive Load Banks are used for power equipment load testing with stepwise loading function Portable with...
The 800kW and 1000kW load banks designed for heavy-duty industrial testing, supporting full-rated continuous loading Equippe...
Full-load testing at 0.8 PF to verify generator performance, voltage regulation, and transient response under realistic operating conditions.
Comprehensive load testing for generator manufacturers to verify performance specifications before delivery to customers.
Mission-critical testing of backup power systems including generators, UPS, and switchgear at realistic power factors.
Dockside and sea trial testing of shipboard power systems with combined resistive-inductive loads matching actual vessel demand.
Rugged load testing solutions for offshore platforms, FPSO vessels, and remote energy facilities in harsh environments.
Testing of solar inverters, wind turbines, and energy storage systems requiring realistic power factor simulation.
Simulates real-world inductive loads at 0.8 power factor — the standard rating for diesel generators and most industrial power systems.
Resistive and inductive sections operate independently, allowing PF=1 resistive-only testing, PF=0 inductive-only, or combined 0.8 PF operation.
High-speed axial cooling fans with integrated air duct structure ensure stable temperatures during continuous full-load operation.
Over-temperature protection, over-current cut-off, over-voltage alarm, fan failure protection, and emergency stop button for maximum safety.
High-quality air-core and iron-core inductors with stable performance, low noise, and long service life under continuous rated operation.
PC-based monitoring and control software with real-time data display, data logging, test report generation, and remote load adjustment.
We can design to your exact specifications — from custom voltage ratings to containerized solutions for large-scale projects.